Blue Asia Labs - خدمات الاختبار والفحص والاعتماد

المدونة

eCall Data Validation: Are You Transmitting More Than the Minimum Required Information?

Contact: [email protected] | WhatsApp: +86 17663606879


In an emergency, an eCall system must transmit the information needed to support an emergency response.

But how can automotive manufacturers ensure that the data transmitted by an in-vehicle emergency system remains within the defined scope?

For OEMs, Tier 1 suppliers and eCall system developers, data content and transmission logic deserve careful attention during system validation.

1. Regulatory Background: Regulation (EU) 2015/758

Regulation (EU) 2015/758 establishes type-approval requirements for the deployment of the 112-based eCall in-vehicle system.

Article 6 addresses privacy and data protection.

In particular, Article 6(8) states that the Minimum Set of Data (MSD) sent by the 112-based eCall system should contain only the minimum information referred to in the cited EN 15722:2011 standard, and that no additional data should be transmitted by the 112-based eCall system.

The same provision also addresses the storage and permanent deletion of MSD data.

2. What Should Automotive Developers Pay Attention To?

A. Data Content

The MSD is not intended to become a general-purpose vehicle data package.

Development teams should review:

  • The data fields included in the MSD

  • The source of each data item

  • The mapping between vehicle information and the applicable MSD definition

  • Whether any additional information is being included in the 112-based eCall transmission

B. Data Transmission

The transmission process should be reviewed against the intended emergency-call workflow.

Relevant project checks may include:

  • Whether transmission is triggered under the intended emergency conditions

  • Whether the correct MSD content is generated

  • Whether the transmitted data matches the prepared data

  • Whether unexpected or additional fields appear in the transmission

C. Data Storage and Deletion

Article 6 also addresses data retention and deletion.

Engineering teams should review:

  • How MSD information is temporarily stored

  • How data is removed when it is no longer required

  • Whether the system supports full and permanent deletion

  • Whether data is accessible outside the 112-based eCall system before an eCall is triggered

3. What About TPS eCall and Other Connected Services?

An important distinction is necessary.

The requirements discussed above concern the 112-based eCall in-vehicle system. They should not automatically be interpreted as a blanket prohibition on all data processing by every connected vehicle service.

Article 6 separately addresses TPS eCall and other added-value services.

It also requires appropriate separation between the 112-based eCall system and additional systems providing TPS eCall or added-value services, including restrictions on the exchange of personal data between them.

This distinction should be reflected in the system architecture and compliance assessment.

4. A Practical eCall Validation Checklist

For project teams, the following checks can help organise validation activities:

Data definition

  • Review the applicable MSD specification and version.

  • Map each transmitted data field to its technical definition.

  • Identify any additional fields in the transmission structure.

Transmission behaviour

  • Verify the data generated during the intended emergency-call scenario.

  • Compare the prepared MSD with the transmitted content.

  • Review abnormal and interrupted transmission scenarios.

Data protection

  • Review data access before eCall activation.

  • Examine data storage and deletion mechanisms.

  • Assess separation between the 112-based eCall and additional service systems.

These are project validation recommendations. The specific test procedures should be determined using the applicable technical and type-approval requirements.

5. An Important Note on Standard References

The consolidated text supplied for this review is dated 9 May 2024.

It is important to distinguish Article 6(8), which refers to EN 15722:2011, from Article 5(8)(d), which lists EN 15722:2020 in its technical standards section.

Project teams should verify the applicable legal text, standard edition and relevant implementing requirements before finalising a compliance assessment.

Final Thoughts

eCall compliance is not only about establishing an emergency call. The accuracy of data content, transmission behaviour, storage and privacy protection are also important parts of the overall system assessment.

At Blue Asia, we support automotive electronics projects through EMC testing, wireless certification and automotive-related testing and compliance services.

For teams developing in-vehicle communication and connected automotive systems, we welcome discussions on potential testing and certification cooperation.


Contact: [email protected] | WhatsApp: +86 17663606879


SHARE

بقلم

Olivia

مهندسو اختبار معتمدون من CNAS يشاركون ملاحظات ميدانية عن RF و EMC والاعتماد العالمي.

اطلب عرض سعر

خدمة العملاء

[email protected] 4000259520 8613534225140
الرئيسية الهاتف الساخن الجوال البريد الإلكتروني
أعلى
اتصل بنا
نستخدم ملفات تعريف الارتباط لتحسين تجربتك على الموقع. باستمرارك في تصفح هذا الموقع، فإنك توافق على استخدامنا لملفات تعريف الارتباط. اطلعه على سياسة ملفات الارتباط.

Cookies

حول ملفات تعريف الارتباط

ملفات تعريف الارتباط هي ملفات نصية صغيرة تُخزَّن على جهازك عند زيارة موقع إلكتروني. يستخدم Blue Asia Labs ملفات تعريف الارتباط لتذكر تفضيل اللغة لديك، والحفاظ على أمان النماذج، وفهم كيفية استخدام الزوار لصفحاتنا.

ملفات تعريف الارتباط التي نستخدمها

ضرورية للغاية — اختيار اللغة وأمان النماذج. لا يمكن تعطيلها.
الأداء — إحصاءات زيارات مجهولة الهوية تساعدنا على تحسين الموقع.

لا نستخدم ملفات تعريف ارتباط إعلانية أو تتبّعية. يمكنك حظر ملفات تعريف الارتباط أو حذفها من إعدادات المتصفح في أي وقت؛ وقد لا تعمل بعض الميزات كما هو متوقع.

التواصل

هل لديك أسئلة حول هذه السياسة؟ راسلنا على [email protected].